Sensors (Basel) ; 23(4)2023 Feb 10.
Article in English | MEDLINE | ID: mdl-36850594

ABSTRACT

Vestibular dysfunction is a disturbance of the body's balance system. The control of balance and gait has a particular influence on the quality of life. Currently, assessing patients with these problems is mainly subjective. New assessment options using wearables may provide complementary and more objective information. Posturography makes it possible to determine the extent and type of posture dysfunction, which makes it possible to plan and monitor the effectiveness of physical rehabilitation therapy. This study evaluates the effectiveness of non-instrumental clinical tests and the instrumental mobile posturography MediPost device for patients with unilateral vestibular disorders. The study group included 40 patients. A subjective description of the symptoms was evaluated using a questionnaire about the intensity of dizziness using the Dizziness Handicap Inventory (DHI) and Vertigo Syndrome Scale-short form (VSS-sf). The clinical protocol contained clinical tests and MediPost measurements using a Modified Clinical Test of Sensory Interaction on Balance. All patients underwent vestibular rehabilitation therapy (VRT) for four weeks. The non-instrumental measurement results were statistically significant, and the best was in the Timed Up and Go test (TUG). In MediPost, condition 4 was the most valuable. This research demonstrated the possibilities of using an instrumental test (MediPost) as an alternative method to assess balance.


Subject(s)
Dizziness , Postural Balance , Humans , Quality of Life , Time and Motion Studies , Computers, Handheld
2.
Article in English | MEDLINE | ID: mdl-36554427

ABSTRACT

The COVID-19 pandemic had a tremendous impact on healthcare systems around the world. This study aims to research the course of surgical treatment in urology during the pandemic in 2020, evaluate the volume of deferred treatment in urology in Poland, and indicate groups of patients that are especially vulnerable to a delay in the delivery of healthcare services. The National Health Found statistics (NHF) database was searched for information on procedures completed in urology departments from 2015 to 2020. Changes in hospital discharges of adults from 2019 to 2021 were investigated using monthly reports of NHF on patient billing groups. Statistics of PSA, testosterone, and creatinine testing were extracted from NHF reports. Annual changes in the number of surgeries were calculated. Then, the estimation of the expected quantity of procedures without the occurrence of the pandemic was performed using linear regression based on data from 2015 to 2020. The estimation was assumed reliable at R2 > 0.8. The difference between collected and estimated data was analysed. In 2020, the volume of radical prostatectomies, cystectomies, and kidney surgeries noted downturns following lockdowns in March and November. All analysed procedures, except radical cystectomy, noted a reduction in the entire year. The declines reached -34% in shockwave lithotripsy, -13% in ureterorenoscopic lithotripsy, -22% in cystolithotripsy, -28% in percutaneous lithotripsy, -12% in transurethral resection of a bladder tumour (TURBT), -31% in transurethral resection of the prostate, -15% in nephrectomy and kidney tumorectomy, and -10% in radical prostatectomy. Among the analysed procedures, only radical cystectomy rates increased 5%. Prostate-specific antigen and creatinine tests fell -17%, and testosterone testing was down -18%. In conclusion, the patients most vulnerable to delayed treatment due to the post-pandemic backlog are those requiring TURBT, kidney cancer operations, and radical prostatectomies. Solving backlogs in urology should prioritise cancer patients and thus requires improved access to cystoscopy, TURBT, diagnoses and surgery of prostate and kidney tumours. Addressing the needs of patients suffering from benign diseases demands appropriate measures to increase the surgical productivity of urology departments.


Subject(s)
COVID-19 , Kidney Neoplasms , Transurethral Resection of Prostate , Urology , Male , Adult , Humans , COVID-19/epidemiology , Pandemics , Poland/epidemiology , Creatinine , Time-to-Treatment , Communicable Disease Control , Testosterone
3.
Otolaryngol Pol ; 76(3): 7-11, 2022 Mar 08.
Article in English | MEDLINE | ID: mdl-35796391

ABSTRACT

<b>Introduction:</b> Mobile posturography is based on wearable inertial sensors; it allows to test static stability (static posturography) and gait disturbances. </br> </br> <b>Aim:</b> The aim of this work was to present the results of research on the innovative MEDIPOST system used for diagnosis and rehabilitation of balance disorders. </br> </br> <b>Material and methods:</b> Fourteen articles published in influenced foreign journals were presented and discussed. The deve-lopment and construction of the device was preceded by a literature review and methodological work. The Dizziness Handi-cap Inventory (DHI) questionnaire was translated and validated. The methodology of posturography with head movements with a frequency of 0.3 Hz was also developed in the group with chronic vestibular disorders. Simultaneous measurements were performed (static posturogrphy vs. MEDIPOST) in the CTSIB-M (Modified Clinical Test of Sensory Interaction in Balance) test in healthy subjects and patients with unilateral peripheral dysfunction.</br> </br> <b>Results:</b> In the posturography with head movements the improvement of sensitivity (67 to 74%) and specificity (65 to 71%) was noted. In the CTSIB-M test the intraclass correlation coefficients for both methods were 0.9. The greatest differences between examinations were observed for the mean angular velocity in the tests on the foam (trials no. 3 and 4), in particular on the foam with eyes closed (trial no. 4 - sensitivity 86.4%, specificity 87.7%). Two functional tests were analyzed: the Swap Seats test and the 360 degree turn test. In the former, the results are studied from 6 sensors - 86% of the true positives and 73% of the true negatives for the fall/ no-fall group classification. The second test differentiates people with vestibular impairment and healthy people. It can be analyzed with 1 (sensitivity 80%) and 6 sensors (sensitivity 86%, specificity 84%). Currently, the MEDIPOST device is in the development and certification phase.


Subject(s)
Postural Balance , Vestibular Diseases , Dizziness/rehabilitation , Humans , Vertigo , Vestibular Diseases/diagnosis , Vestibular Diseases/rehabilitation
4.
Sci Rep ; 12(1): 7472, 2022 05 06.
Article in English | MEDLINE | ID: mdl-35523836

ABSTRACT

Vestibular impairments affect patients' movements and can result in difficulties with daily life activities. The main aim of this study is to answer the question whether a simple and short test such as rotation about a vertical axis can be an objective method of assessing balance dysfunction in patients with unilateral vestibular impairments. A 360˚ rotation test was performed using six MediPost devices. The analysis was performed in three ways: (1) the analytical approach based only on data from one sensor; (2) the analytical approach based on data from six sensors; (3) the artificial neural network (ANN) approach based on data from six sensors. For approaches 1 and 2 best results were obtained using maximum angular velocities (MAV) of rotation and rotation duration (RD), while approach 3 used 11 different features. The following sensitivities and specificities were achieved: for approach 1: MAV-80% and 60%, RD-69% and 74%; for approach 2: 61% and 85% and RD-74% and 56%; for approach 3: 88% and 84%. The ANN-based six-sensor approach revealed the best sensitivity and specificity among parameters studied, however one-sensor approach might be a simple screening test used e.g. for rehabilitation purposes.


Subject(s)
Movement , Vestibular Function Tests , Humans , Neural Networks, Computer
5.
Sensors (Basel) ; 22(6)2022 Mar 12.
Article in English | MEDLINE | ID: mdl-35336379

ABSTRACT

Balance disorders are a growing problem worldwide. Thus, there is an increasing need to provide an inexpensive and feasible alternative to standard posturographic platforms (SP) used for the assessment of balance and to provide a possible solution for telemonitoring of patients. A novel mobile posturography (MP) MediPost device was developed to address these issues. This prospective study used a Modified Clinical Test of Sensory Interaction on Balance to evaluate healthy individuals and patients with a unilateral vestibular disorder through SP and MP simultaneously. The control group included 65 healthy volunteers, while the study group included 38 patients diagnosed with a unilateral vestibular deficit. The angular velocity values obtained from both methods were compared by intraclass correlation coefficients (ICC) and Bland−Altman plot analysis. Diagnostic capabilities were measured in terms of sensitivity and specificity. The ICC between the two methods for conditions 2−4 was indicative of excellent reliability, with the ICC > 0.9 (p < 0.001), except for Condition 1 (standing stance, eyes open) ICC = 0.685, p < 0.001, which is indicative of moderate reliability. ROC curve analysis of angular velocity for condition 4 represents the most accurate differentiating factor with AUC values of 0.939 for SP and 0.953 for MP. This condition also reported the highest sensitivity, specificity, PPV, and NPV values with 86.4%, 87.7%, 80%, and 90.5% for SP, and 92.1%, 84.6%, 77.8%, and 94.8% for MP, respectively. The newly developed MediPost device has high sensitivity and specificity in distinguishing between healthy individuals and patients with a unilateral vestibular deficit.


Subject(s)
Postural Balance , Vestibular Diseases , Humans , Physical Therapy Modalities , Prospective Studies , Reproducibility of Results , Vestibular Diseases/diagnosis
6.
Polymers (Basel) ; 13(23)2021 Nov 27.
Article in English | MEDLINE | ID: mdl-34883643

ABSTRACT

One of the examples of physical starch modifications is the retention of a starch suspension in water having a temperature slightly lower than the pasting temperature (annealing). The aim of this study was to investigate the effect of the annealing process performed at various temperatures as the first stage of starch modification. The annealed starch preparations were then esterified using acetic acid anhydride. Finally, the annealed and acetylated starch preparations were determined for their properties. The annealing of starch before acetylation triggered changes in the properties of the modified preparations. It contributed to a higher degree of starch substitution with acetic acid residues and to the increased swelling power of starch. Both these properties were also affected by the annealing temperature. The highest resistance to amylolysis was found in the case of the starch preparation annealed at 53.5 °C and acetylated. The double modification involving annealing and acetylation processes increased the onset and end pasting temperatures compared to the acetylation alone. Similar observations were made for the consistency coefficient and yield point.

7.
Clin Interv Aging ; 15: 2397-2406, 2020.
Article in English | MEDLINE | ID: mdl-33376315

ABSTRACT

OBJECTIVE: The gold standard for objective body posture examination is posturography. Body movements are detected through the use of force platforms that assess static and dynamic balance (conventional posturography). In recent years, new technologies like wearable sensors (mobile posturography) have been applied during complex dynamic activities to diagnose and rehabilitate balance disorders. They are used in healthy people, especially in the aging population, for detecting falls in the older adults, in the rehabilitation of different neurological, osteoarticular, and muscular system diseases, and in vestibular disorders. Mobile devices are portable, lightweight, and less expensive than conventional posturography. The vibrotactile system can consist of an accelerometer (linear acceleration measurement), gyroscopes (angular acceleration measurement), and magnetometers (heading measurement, relative to the Earth's magnetic field). The sensors may be mounted to the trunk (most often in the lumbar region of the spine, and the pelvis), wrists, arms, sternum, feet, or shins. Some static and dynamic clinical tests have been performed with the use of wearable sensors. Smartphones are widely used as a mobile computing platform and to evaluate the results or monitor the patient during the movement and rehabilitation. There are various mobile applications for smartphone-based balance systems. Future research should focus on validating the sensitivity and reliability of mobile device measurements compared to conventional posturography. CONCLUSION: Smartphone based mobile devices are limited to one sensor lumbar level posturography and offer basic clinical evaluation. Single or multi sensor mobile posturography is available from different manufacturers and offers single to multi-level measurements, providing more data and in some instances even performing sophisticated clinical balance tests.


Subject(s)
Aging/physiology , Dizziness/rehabilitation , Mobile Applications , Postural Balance/physiology , Wearable Electronic Devices , Accidental Falls/prevention & control , Aged , Dizziness/diagnosis , Humans , Reproducibility of Results
8.
Pharmacy (Basel) ; 8(1)2020 Mar 09.
Article in English | MEDLINE | ID: mdl-32182834

ABSTRACT

Background: The introduction of a medicines verification and decommissioning system into the hospital pharmacy may result in an increased workload for pharmacy staff. The pilot implementation allows us to understand all the implications of the process, optimize process workflows, and estimate the time and cost of implementation. Methods: All the packages received at the hospital pharmacy had a 2D data matrix codes and were scanned. We analyzed the time needed to unpack a variety of products, scan them, and receive the notification. Results: In total, 144 packages were scanned at an average time of 3.05 s, with most (86.9%) under 4 s. Manual decommissioning using handheld scanners was less efficient than the automated solution tested and resulted in an additional 0.4 full-time equivalent hours per million packages per year. The pattern and total time of manual scanning depended not only on the quantity but also the size of the package and type of packing. Conclusions: This evaluation of scanning performance allows optimizing the process at operational, technical, and resource levels for medicine verification and decommissioning.

10.
Pharmacy (Basel) ; 5(4)2017 Nov 09.
Article in English | MEDLINE | ID: mdl-29120385

ABSTRACT

BACKGROUND: Recently, the European Union has introduced the Falsified Medicines Directive (FMD). Additionally, in early 2016, a Delegated Act (DA) related to the FMD was published. The main objective of this study was to evaluate the usefulness of external audits in the context of implementing new regulations provided by the FMD in the secondary care environment. METHODS: The external, in-person workflow audits were performed by an authentication company in three Polish hospital pharmacies. Each audit consisted of a combination of supervision (non-participant observation), secondary data analysis, and expert interviews with the use of an independently designed authorial Diagnostic Questionnaire. The questionnaire included information about hospital drug distribution procedures, data concerning drug usage, IT systems, medication order systems, the processes of medication dispensing, and the preparation and administration of hazardous drugs. Data analysis included a thorough examination of hospital documentation in regard to drug management. All data were subjected to qualitative analysis, with the aim of generating meaningful information through inductive inference. RESULTS: Only one dispensing location in the Polish hospitals studied has the potential to be a primary authentication area. In the audited hospitals, an Automated Drug Dispensing System and unit dose were not identified during the study. Hospital wards contained an enclosed place within the department dedicated to drug storage under the direct supervision of senior nursing staff. An electronic order system was not available. In the largest center, unused medications are re-dispensed to different hospital departments, or may be sold to various institutions. Additionally, in one hospital pharmacy, pharmacists prepared parenteral nutrition and chemotherapeutic drugs for patients admitted to the hospital. CONCLUSIONS: External audits might prove beneficial in the course of introducing new regulations into everyday settings. However, such action should be provided before the final implementation of authentication services. To sum up, FMD can impact several hospital departments.